FECD Front end card data. One for each calibration signal. =========================================================== Contact: N. West, Oxford. Revision History:- ================ 3.01 N. West First version. Description ----------- These banks contain the information from any FEC channel, which is associated with a calibration signal rather than a PMT and which is above threshold for a particular trigger. The format is identical to the PMT bank apart from:- +1 I KPMT_PN Duplicate of _PIN CCC DAQ Circuit Number as there is no associated tube number. Note that there are NO corresponding Px and PIx banks for this data as the plan is to phase out those banks. The FECD bank is Created by : MCO: Monte Carlo Updated by : UCL: Event UnCalibration Recreated by : UPK: Event Unpacker Updated by : CAL: Event Calibration