Next: The Time Spoiler Processor
Up: User Control
Previous: To Create ANXX Banks
Contents
- See anxx_load.cmd for instance;
- In anxx_control.dat,
- if anxx_pca.dat and anxx_neutrino.dat are used, 31st word
is set to be 1, 32nd word is set to be -9, and 33rd word is
set to be 3;
- if anxx_n16.dat and anxx_neutrino.dat are used, 31st word
is set to be -9, 32nd word is set to be 2, and 33rd word is
set to be 3;
- the rest words are not used in this stage.
- in the analyst's programs, call anxx_is_online(lcn,mask1,mask2)
to check whether or not a given channel is online by providing
lcn (logical channel number), mask1, and mask2.
- In general, PCA (or N16) data is used for checking TAC, QHS, QHL,
QLX, and EHS/ELX gain ratio, and neutrino data is used for checking
synclear error, cell id increment, low occupancy, excessive orphan
hits, and high occupancy. For example, if one would like to see
if a tube fails due to TAC low side (2), TAC high side(3), QLX low
side(11), QLX high side (12), EHS/ELX gain ratio (18), synclear
error (13), and low occupancy (17), then the analyst needs to
provide
- mask1 =
;
- mask2 =
Next: The Time Spoiler Processor
Up: User Control
Previous: To Create ANXX Banks
Contents
sno Guest Acct