$^{8}$Li Generic Calibration Source

The $^{8}$Li calibration source consists of three regions:-

User Control

The user control of this source is identical to that of the generic inner calibration source, except that there are now THREE embedded regions, and all three must be of the same type, i.e. three spheres or three cylinders. The default specification of the geometry is as follows :-



Region Medium Cylinder Radius Cylinder Half Height  
LI8_CAN Stainless Steel 1.17 cm 50.0 cm  
LI8_CATH Stainless Steel 1.105 cm 50.0 cm  
LI8_GAS Air 1.105 cm 50.0 cm  


To set off $^{8}$LI events within this source use the command file: calibration_8li_generic.cmd