Titles: SODG ============ Contact: S. Biller, Oxford. Revision History:- ================ 3.01 S. Biller First version Titles Files ------------ Verification ------------ Description ----------- N16/N17/Li8 gas source description Data Words ---------- Data types: B(bit), I, F, D(double), H(hollerith 4 char) +1 I KSODG_MON Electronics channel for monitor pmt/wire +2 I KSODG_DTG DT generator on/off (0=off, 1=on) +3 F KSODG_TPOS Target chamber vertical setpoint position +4 F KSODG_PG1 Gauge 1 target pressure +5 F KSODG_PG2 Gauge 2 target pressure +6 F KSODG_PG3 Gauge 3 target pressure +7 F KSODG_PG4 Gauge 4 target pressure +8 F KSODG_PG5 Gauge 5 target pressure +9 F KSODG_PG6 Gauge 6 target pressure +10 F KSODG_VG1 Vacuum gauge 1 target pressure +11 F KSODG_VG2 Vacuum gauge 2 target pressure +12 F KSODG_FL_CO2 Target CO2 flow rate +13 F KSODG_FL_HE Target Helium flow rate +14 F KSODG_FL_O2 Target Oxygen flow rate +15 F KSODG_NEUT Fast neutron flux calibration +16 F KSODG_NRAD Neutron radiation monitor max safty value +17 F KSODG_PMTV Nominal PMT voltage (N16/N17) +18 F KSODG_WRV nominal wire voltage (Li8) +19...+24 F spare