Titles: MCEC ============= Contact: D. Wark, Oxford. Revision History:- ================ 3.00 D. Wark First version. Titles Files ------------ mc_generator.dat Verification ------------ Description ----------- This bank controls the simulation of the electronics calibration. Data Words ---------- Fixed length Database Header. See titles_dbhdr.html Line Type Variable Description ---- ---- -------- ----------- 1 I EC_FIRST Lowest tube to calibrate. 2 I EC_TYPE Type of cal (1=ped., 2=t slope, 3= q slope) 3 I EC_GROUPS Number of groups of tubes. 4 I EC_NTUBES Number of tubes in each group. 5 I EC_NPULSES Number of pulses in each channel. 6-8 F EC_T_PED Param. for t pedestal dist. (see EC_dT) 9-14 F EC_T_PAR Param. for t slope dist. (see EC_dT) 15-23 F EC_Q_PED Param. for q pedestal. (see EC_dQ) 23-34 F EC_Q_PAR Param. for q slope dist. (see EC_dQ) 34 F Pulser Freq Pulser rate (Hz).