bank_rldt


                   RLES      Run Log Electronics Status bank
                   =========================================
 
    Contact:  N. McCauley, Oxford.
 
    Revision History:-
    ================
 
    4.02  N. McCauley    First Version
    5.01  N. McCauley    Add ANxx words.


 
Description
-----------
 
This bank contains a summary of the electronics status at the beging of the run, obtained from the DQxx banks.

The bank number is the run number.
 
Reference Links
---------------
 
    None.
 
Structural Links
----------------

    None.
 
Status Bits
-----------
 
Note: Any status bit parameters are defined to work with bit functions such as
      IAND and BTEST.
 
Data Words
----------
 
    Data types: B(bit), I, F, D(double), H(hollerith 4 char)
 
  Wd Typ     Mnem.                           Description

 +1   I  KRLES_CRATE_DAQ               Number of crates online to DAQ.
 +2   I  KRLES_CRATE_HV                Number of create with HV on.
 +3   I  KRLES_CHAN_NOT_OP             Number of channels operational.
 +4   I  KRLES_CHAN_LIVE               Number of channels live to analysis. See note 1. 
 +5   I  KRLES_CHAN_SEQ                Number of channels with sequncers enabled.
 +6   I  KRLES_CHAN_TRIG               Number of channels with 100ns triggers enabled.
 +7   I  KRLES_CHAN_POS_BLIND_FLASH    Number of channels that are potential source of blind flashers. See note 2.  
 +8   F  KRLES_CHAN_AVE_VT             Average Channel threshold.
 +9   I  KRLES_PMT_LIVE                Number of PMTs live to analysis. See note 1. 
 +10  I  KRLES_PMT_SEQ                 Number of PMTs with sequncers enabled.
 +11  I  KRLES_PMT_TRIG                Number of PMTs with 100ns triggers enabled.
 +12  I  KRLES_PMT_POS_BLIND_FLASH     Number of PMTs that are potential source of blind flashers. See note 2. 
 +13  F  KRLES_PMT_AVE_VT              Average PMT threshold.
 +14  I  KRLES_OWL_LIVE                Number of OWLs live to analysis. See note 1. 
 +15  I  KRLES_OWL_TRIG                Number of OWLs with 100ns triggers enabled.
 +16  I  KRLES_BUTT_LIVE               Number of BUTTs live to analysis. See note 1. 
 +17  I  KRLES_NECK_LIVE               Number of NECKs live to analysis. See note 1. 
 +18  I  KRELS_LG_LIVE                 Number of low gain tubes live to analysis. See note 1. 
 +19  I  KRLES_FECD_SEQ                Number of FECDs with sequncers enabled.
 +20  I  KRLES_FECD_TRIG               Number of FECDs with 100ns triggers enabled.
 +21  I  KRLES_ANXX_ENE_ONLINE         Number of PMTs live to analysis passing ANxx energy analysis cuts.
 +22  I  KRLES_ANXX_FIT_ONLINE         Number of PMTs live to analysis passing ANxx reconstrution analysis cuts.
 +23  I  KRLES_ANXX_MU_ONLINE          Number of PMTs live to analysis passing ANxx muon analysis cuts.


Notes ----- 1) A channel is defined as live to analysis if: -The Channel is opperational. -The Channel relay is on. -The Channel has HV on. -The Channel sequncer is enabled. -The PMTIC resistor is present. -The Threshold is less than 255. 2) A channel is defined as a potential source of blind flashers if: -The Channel relay is on. -The Channel has HV on. -The Channel sequncer is disabled. Go Back to the Snoman Companion Top Page