next up previous contents
Next: Electronics Calibration Up: The Runlog Processors Previous: RLO: Runlog Output   Contents

LSP: Livetime Summary Processor

The livetime summary processor uses RLOG and RLDT banks to calculate and report a series of important livetime quantities and a given a given run set. In particular LSP is used in combination with the RLR and the run list option to provide an livetime summary for a neutrino data set. The principle feature of LSP is that the livetime (and deadtimes) are reported as a function of three different variables, the hour of the day, the month of the year and most importantly for day-night analyses the postition of the sun.

These values are reported in a summmary test file. The name of this file will be 'livetime.dat', unless other set by the use of the command:

file lsp 1 livetine.dat
The same results can also be reported in the form of histograms is the command
file lsp 2 livetine.hbk
is specified.

LSP has two inputs in the TLSP 1 titles bank that can be adjusted. The first of these is a switch that specifies whether or not data splitting is used to report for a blind of non-blind data set. The second inpuit is the size of the time step used in the calculation of the livetime as a function of the different variables.


next up previous contents
Next: Electronics Calibration Up: The Runlog Processors Previous: RLO: Runlog Output   Contents
sno Guest Acct 2009-09-09