next up previous contents
Next: Step 2:- FT1_COM.INC Up: Adding a New Fitter Previous: Adding a New Fitter   Contents

Step 1:- FITTER.DAT

This file contains the titles banks for each fitter.

                      :
                      :
                      :
               MORE TITLES BANKS
                      :
                      :
                      :
*---------------------------------------------------------------
*---
*---    User Fitter 1
*---
*---    Contact:  N. West  Oxford.
*---
*---------------------------------------------------------------
*DO  TFT1   1              #.  Bank for user fitter 1 parameters
#.
#.    Database Header (to be defined)
#.
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
 
#.    User Data.
 
3                          #. Minimum PMT hits for fit.
10.                        #. Maximum RMS for fit.
*---------------------------------------------------------------
                      :
                      :
                      :
               MORE TITLES BANKS
                      :
                      :
                      :

Each fitter draws its input constants (i.e. NOT the PMT data) from its own titles bank in the file FITTER.DAT. For FT1 the format and mnemonics for these constants are defined in FT1_COM.INC described below. As can be seen above the TFT1 bank currently supplies the FT1 fitter with 2 input constants. The user should change this list of constants to supply their fitter with whatever information it needs.



sno Guest Acct 2009-09-09