=========== "Old-Style" ECA Format ===========
Introduction
This processor analyses the ZDAB data containing electronics calibration,
determines charge and time pedestals and slopes and creates titles files
containing these data.
Two files are required:-
- ECA_READ.CMD
SNOMAN cmd file, which basically defines the input ZDAB files
- ECA_DATA.DAT
TITLES Bank which sets:-
- Which of the three calibrations to run
- Tolerances for various parameters
- Which crates to include in the calibration
- Range of the number PMT's required in an event to accept that event
- DAQ to pe/ns conversion constants
Output Files
Each calibration has four types of output files:-
TITLES files
All TITLES files have the same
TITLES FORMAT
NTUPLES
The ntuples are each 19x16x32x16 long with the crate, card, channel and cell
number accompanying each of the calculated quantities in the TITLES banks.
BINARY files
These contain the identical information that exists in the TITLES banks except
that they are written out with a binary FORTRAN WRITE statement for those who
like the simple life.
ASCII file
Listing the cells that fall below the tolerance levels set in
ECA_DATA.DAT