Age | Commit message (Collapse) | Author |
|
get_hough_transform()
This commit adds two improvements to the quad fitter:
1. I updated quad to weight the random PMT hit selection by the probability
that the PMT hit is a multiphoton hit. The idea here is that we really only
want to sample direct light and for high energy events the reflected and
scattered light is usually single photon.
2. I added an option to quad to only use points in the quad cloud which are
below a given quantile of t0. The idea here is that for particles like muons
which travel more than a few centimeters in the detector the quad cloud usually
looks like the whole track. Since we want the QUAD fitter to find the position
of the *start* of the track we select only those quad cloud points with an
early time so the position is closer to the position of the start of the track.
Also, I fixed a major bug in get_hough_transform() in which I was using the
wrong index variable when checking if a PMT was not flagged, a normal PMT, and
was hit. This was causing the algorithm to completely miss finding more than
one ring while I was testing it.
|
|
This commit updates get_event() to flag PMT charges below qlo, which is the
minimum charge value that we compute the charge PDFs for. This is to prevent
the likelihood from returning nan.
|
|
Also, call this function when computing the psi parameter in nll_best().
|
|
This commit updates the charge likelihood calculation to calculate:
P(hit,q|n) = P(q|hit,n)*P(hit|n)
This has almost no effect on the fit results, but is technically correct.
|
|
|
|
This commit adds lots of comments to sno_charge.c and makes a couple of other
changes:
- use interp1d() instead of the GSL interpolation routines
- increase MAX_PE to 100
I increased MAX_PE because I determined that it had a rather large impact on
the likelihood function for 500 MeV electrons. This unfortunately slows down
the initialization by a lot. I think I could speed this up by convolving the
single PE charge distribution with a gaussian *before* convolving the charge
distributions to compute the charge distributions for multiple PE.
|
|
|
|
|
|
This commit adds a fast function to calculate the expected number of PE at a
PMT without numerically integrating over the track. This calculation is *much*
faster than integrating over the track (~30 ms compared to several seconds) and
so we use it during the "quick" minimization phase of the fit to quickly find
the best position.
|
|
|